| Description: 8-way interaction module is mainly used for linkage control, home appliances, lighting, etc.
1. Modules and host connection methods: Eight output module and the host with the keyboard and keyboard interface connected to the host
2. Wiring methods output linkage: The linkage device to be the power circuit loop or a line cut signal receiving module, respectively, the output any way normally closed (NC, COM) or normally open (NO, COM) output port
3、 Set Output Module
Format: 8 lines output time: 35 + Line Number (1--8) + Seconds (4 bites) + F4 Seconds:0000—9999 seconds ( Factory setting: 60 seconds)
8 lines output requirement: 36 + Line Number (1--8) + Requirement 1 (2 bites) + Requirement 2 (2 bites) + F4 (Factory setting: 0)
8 lines output corresponding requirement: 00 means siren following, 01—16 is corresponding Zone alarm output
17 means Zone alarm output
18 means press emergency A key
19 means ARM
20 means DIS-ARM
21 means ARM with output, and DIS-ARM without output Remote control of module output: * + approach + state + (approach 1-8, expresses 1-8 roads , state 1 opens output , 2 closes the output) for example: in the state by remote control +1 +1 + * #(That opens the first output) 1 + 0 + # (expression being closed down or opens the first output) |